The Rayburn Cookmaster Plus 208K is a cookerproviding domestic hot water and cooking facilities. It isavailable with a vertical flue outlet only, with
It should be in accordance also with any relevantrequirements of the Local Authority and the relevantrecommendations of the following current British
guidance:-The cross sectional area of the flue serving theappliance must not be less than the area of the flueoutlet of the appliance and be at least
Detailed recommendations for air supply are given inthe current Building Regulations J1/4/5.The following notes are intended to give generalguidance:-
space of at least 25mm.Spaces around the flue pipes passing through walls orfloors should be sealed against the passage of smokeand flame.The applianc
1. Open outer burner door and lift/remove inner burner door.2. Withdraw oil burner base assembly and place on a work surface. Locate the perforated sh
1. Open all oil valves to allow oil into the oil control valve. It may be necessary to purge the oil line to prevent airlocking.2. Depress the trip le
assembly, checking that the shell assembly seats airtightly on the burner bases.NOTE: ENSURE ‘CUT-OUTS’ ON BURNER WICKSLINE UP WITH OIL CHANNELS ON BU
1. Advise the User of the precautions necessary toprevent damage to the hot water system and to thebuilding in the event of the system remaininginoper
It is important that a 6 monthly service be carried out bya competent Service Engineer and it is recommendedthat a contract be made with such an Engin
The cooking performance features of the popular andproven solid fuel Rayburn Cookers have beenpreserved and integrated into the Rayburn Cookmaster200K
12For further advice or information contactyour local distributor/stockistWith Aga’s policy of continuous productimprovement, the Company reserves the
Product Technical GuideU.K EditionCookmaster 200KCookmaster 200KHeatranger Heatranger 208K208KSpecification Appliance weight (uninstalled) ---
Dimensions A Rayburn is assembled from individual enamelledcast-iron components, which may cause the productto vary slightly in its overall dimension
GeneralInstallation of an oil-fired range cooker is a ‘controlled service’ and is therefore notifiable toBuilding Control, unless self certified by a
Fuel connection is 1/4” BSP, into the OCV fixed to the left hand side panel. The OCV cannot berelocated elsewhere.A remote acting fire-valve rated at
Flue systemThis appliance is designed to work on an Open or Conventional flue only, with a minimumeffective height of 4.5 metres. A negative flue dra
Domestic Hot Water (Model 308K)The cast-iron heat exchanger has avitreous lining, with a maximum out-put of 2.3kW/hr when the burner isat high fire, e
This leaflet is a pre-installation guide only.For further advice or information please refer to the product owners manual or contactyour local Rayburn
1. Remove the oil control valve cover, then depress the trip lever D on the front of the oil control valve and turn the cooker oil control valve knob
Turn the control knob C to No.1 which give the lowestburning rate and will maintain an oven temperature ofabout 150°C-170°C. At a higher setting, the
REMEMBER: BE CAREFUL OF THE HOT APPLIANCE.DO NOT USE A STEAM CLEANER TO CLEAN THISCOOKER.To keep the vitreous enamelled surface bright and clean,wipe